HMI Display
1. Goal
- Activate a display that has already been wired up to a Charge Controller
- Get an overview over what type of information is displayed
- Changing languages
- How to set up a single display with 2 Charge Controllers (Master-Slave)
2. Overview
A correctly set up display shows the following information to EV drivers while the charging is in progress:
- Charging time
- Energy
- Power
3. Hardware
The DPM2x16FP Display-Module is meant to be used with the CC613 Charge Controller. It visualizes the status by being integrated in the charging station.
3.1. Associated equipment
- Charge Controller: CC613, CC612 and ICC1324
- RFID Card Reader: RFID105-L1, RFID117-L1 and RFID114
3.2. Installation
The Display module can be connected to the charge controller using a standard RJ45 cable. The second RJ45 cable interface socket is used to connect to the RFID module. The CC612 and the RFID module can be connected using either RJ45 cable interface socket. The RJ45 sockets are interchangeable.
4. Activating the display
The Display is active by default.
5. Relevant configuration options
If | and | set Type of Display to |
---|---|---|
No display is in use | Display not configured | |
A display is connected | you don't want the display to show information | Display not in use |
you want the display to show information | Bender LCD-Module DPM2x16FP |
6. Configuring the display on Master-Slave and Standalone Charging Stations
Location in Legacy Configuration Interface | Parameter | Value | Information shown |
---|---|---|---|
Manufacturer | Mode for Display | Main | The Displays shows the information of the main Charge Controller. |
Master-Slave | The Display is in split mode. Information of both Charge Controllers displayed at the same time. |
6.1. Changing what information is displayed
if you want this to be shown on the display | set this value |
---|---|
Display charging time | On |
Display energy | On |
Display power | On |
6.2. Changing the display language
-
Apply the following configuration:
Location in Legacy Configuration Interface | Parameter | Value | Info |
---|---|---|---|
Operator | Language of Display | English | Shows the information in English. |
Deutsch/German | Shows the information in German. | ||
Multi-Language EN-DE-FR-NL> | Shows the info in different languages by alternating the messages shown on the display |
- At the bottom of the Configuration Interface, click , then click to apply the changes