Access the Dashboard
Goal
- Open the PENDING to configure a Laderegler through Ethernet or USB
Before you begin
- Establish a connection between your laptop and Laderegler. Follow this guide to learn how.
- Wait for the Laderegler's Status LED to blink green
Steps
- Browse to http://192.168.123.123 with your web browser
You should see a login screen now.
- Log into the PENDING as a Manufacturer using the default credentials below.
Default Dashboard credentials
These are the factory-set credentials:
Login | username | default password | Dashboard availability | Info |
---|---|---|---|---|
Manufacturer | manufacturer | orange_zone | Legacy Dashboard | |
Operator | operator | yellow_zone | Legacy Dashboard & Dashboard |
Based on you logging in as a Ladepunkt Betreiber or Manufacturer, you'll see different configuration options. The Manufacturer options are more extensive.
Overview over the Dashboard
The PENDING is a web-based user interface that comes bundled with the Charge Controller. We enable Manufacturers to align the Dashboard theme to their branding.
Common things you can do in the Dashboard
Here are some things you as a Manufacturer and Operator can do using the Dashboard:
- Configure Master-Slave setups on double Charging Stations
- Enable/disable various software functions
- Configure Backend connections
- Set up Load Management
- And much more
Legacy versus v2.0 Dashboard
The Charge Controller currently ships with a Legacy and v2.0 PENDING. One of the first recommended steps is to set the default Dashboard to v2.0.
When referring to the Dashboard, we refer to the Dashboard v2.0 unless otherwise specified.
Some Manufacturer options are being ported over to v2.0. In the meantime, you'll have to switch to the Legacy Dashboard to perform some configurations.